Product information
HVLS FAN (High Volume Low Speed)
ENERGY SAVING AIR-CONDITIONER SOLUTION
Compared to the much higher number of traditional fans needed for simply cooling, when installed in large spaces, HVLS fans will optimize three-way convection to deliver cool air while still saving energy.
Effective ventilation by creating air circulation, suitable for factory warehouses, sports halls, gyms, etc.
Balance temperature – humidity evenly throughout the space. Reduce cooling or heating costs for four seasons all year round.
Suspension system: HVLS fan with 5 aluminum blades and shaft mounted with high strength bolts; along with a 5-blade safe holder.
Wing Coupling: A high-strength, high-fatigue rigid coupling holds the propeller and main drive vane.
Meeting most of the different large and small spaces, the HVLS fan – powered by MTA Tech is the latest PMSM motorized generation, the quietest in its class.
HIGH PERFORMANCE ENGINE WITH NO NOISE
Ranked 1st in terms of quietness, the high performance product brings you the feeling of relaxation in a noise-free space
PERMANENT MAGNETS
Neodymium magnets, which are the important components of motor rotating parts, can withstand high temperatures of 150°C. In addition, the heat generated when driving the motor is directed to the stator and designed to dissipate automatically through the radiator ribs.
IPM ENGINE
The product uses an internal rotor motor (IPM) structure with a permanent magnet inside the rotor. By attaching a blade to the inside face of the rotor, and placing a stator on the outside, the gravity of the motor rotating part is reduced and the fan rotation is stabilized.
1 HVLS FAN COVERING 2,000M2
The fan creates an extremely large airflow of 0.5m/s that spreads to a distance of 25m from the center of the fan.
CREATE AIR CIRCULATION THROUGH 3-WAY CONVECTION
The product creates a three-way convection light breeze from above, overcoming obstacles,
ENERGY SAVING
High-efficiency, energy-saving motor reduces operating costs – Reduces power consumption by 90%!
For example, in an area of 2,000 ㎡ 65 industrial fans φ450 must be used
We only need to use a single HVLS fan to cover a wide area.
Energy-saving HVLS fan can help to reduce operating costs for workspace optimization.
Why choose MTA TECH
DIFFERENCE BETWEEN MTA TECH’S HVLS INDUSTRIAL CEILING FAN AND TRADITIONAL HVLS INDUSTRIAL CEILING FAN
To address the need for effective ventilation and cooling in spaces, many companies are transitioning to the use of new types of fans such as HVLS industrial ceiling fans.
However, many customer still do not understand the difference between the new HVLS industrial ceiling fan and the traditional HVLS industrial ceiling fan. Therefore, this article will compare these two types of fans to help you understand the differences and why you should choose MTA TECH’s HVLS fan.
HVLS industrial ceiling fans are a type of industrial ceiling fan with large fan blade diameters, typically ranging from 3.3m to 7.3m, capable of moving large volumes of air in spacious areas.
Currently, in the Vietnamese market, there are two main types of motors commonly used in HVLS fans, which are gearbox motors and permanent magnet synchronous motors (PMSM):
Performance: MTA TECH’s HVLS fan utilizes aluminum alloy blades with PMSM motors and a 3D air circulation mechanism, providing greater airflow and higher efficiency compared to traditional HVLS fans that only use gearbox motors as the main motor. This means that MTA TECH’s HVLS fan saves more energy during operation. Furthermore, MTA TECH’s HVLS fan provides natural cool air, creating a very comfortable feeling for users.
Noise Level: PMSM motors have lower noise levels compared to gearbox motors. This is because PMSM motors use a rotor structure with permanent magnets, operating on a synchronous rotor and stator drive mechanism, minimizing noise compared to gearbox motors (noise levels below 38dB).
Safety: MTA TECH’s HVLS fan has higher safety levels compared to traditional HVLS fans. This is because PMSM motors do not have moving parts, minimizing errors due to component wear. Additionally, MTA TECH’s HVLS fan is designed with three sturdy protection layers, minimizing vibration and reducing accidents caused by vibration or breakage.
Lifespan: Gearless PMSM motors can avoid gear wear and oil leakage, resulting in a longer lifespan compared to gearbox motors and especially without the need for periodic maintenance.
Cost: The only drawback of PMSM motors is that they are more expensive than gearbox motors. This is because PMSM motors have higher efficiency and reliability, requiring the use of better materials and manufacturing technology. However, MTA TECH has also addressed this weakness and brought the best products to the market at extremely competitive prices.
DIFFERENCES IN TECHNOLOGY
|
MTA TECH’S HVLS FAN |
TRADITIONAL HVLS FAN |
|
|
HVLS Fan Blades |
Material: Aluminum-magnesium alloy. Each blade thickness is 2mm, securely attached with a steel plate inside about 30cm long by 3 positioning pins. Not easily deformed or bent. |
Material: Aluminum alloy Just turning screws can easily deform and bend. |
|
Motor |
Gearless permanent magnet synchronous motor. IP44 ~ 64 protection rating. Power 0.6 to 1.2kW. Noise ≤ 38dB No maintenance required, lifespan up to 10~15 years. Energy-saving and operational cost-saving. |
Reduction gear motor. No dust or water resistance standards. Power 0.4 to 1.5kW. Noise Regular maintenance required, motor maintenance, lifespan 3~5 years. Not energy-efficient. |
|
Safety Design |
Vibration resistance 3-level safety cable system. When the fan runs, the blades rotate but the motor does not |
When the fan runs, both the blades and the motor rotate |
Through comparing MTA TECH’s HVLS fan and traditional HVLS fan, we can clearly see the differences in performance, energy saving, and stability of MTA TECH’s fan. With advanced technology, intelligent design, and superior features, MTA TECH’s HVLS fan not only brings comfort and convenience to users but also contributes positively to environmental protection and cost savings for businesses. Therefore, if you are looking for an advanced and efficient solution for ventilation and cooling systems, MTA TECH’s HVLS fan is an excellent choice for you.
Additionally, we are the only supplier in the market of the third-generation HVLS fan using the most advanced PMSM motor. And also the number one HVLS fan in the Japanese market.
Contact MTA TECH for advice and instructions on using effective and safe products.










